WKX-AX end switches are used in safety circuits of mining machines. There are two available versions: stable switch type WKA-AX/B used as end switch and unstable-signal switch type WKA-AX/S intended to monitor the movement of mining machines and devices, for example the presence of cable railway transport unit, the position of ventilation sluice door etc.
Technical data
| ATEX certificate number | FTZÚ 04 ATEX 0160 |
| Working voltage | max. 90V |
| Connection current | max. 1,5A |
| Overall number of contacts | 4 |
| Maximum supply voltage | 42 V for ia or ib circuits |
| Device category | I M1 |
| Casing type | Ex ia I |
| Working temperature range | 0°C ÷ 50°C |
| Casing protection degree | IP54 |
| Width x Height x Depth | 90 x 55 x 50 mm |
| Weight | 1,5 kg |
| Number of outlets / cable connectors | 1 |