Skip to content
ATUT logo
// ATUT-CT

ATUT-CT - Temperature sensor

You will switch off the device before overheating causes real damage—two independent control circuits in a single head.

ATUT-CT, czujnik temperatury do obwodów sterowania automatyki w strefach zagrożonych wybuchem

// DESCRIPTION

What it is

The ATUT‑CT temperature sensor operates in automation system control circuits and features two independent control circuits. The measuring circuit continuously measures temperature and switches off the device once a threshold set by you is exceeded. The tripping circuit opens the contacts when the temperature of the measuring head exceeds 85°C, regardless of your settings.

You transmit signals from both circuits to visualisation and recording devices, allowing you to see the temperature and device status in real time. You can install it in rooms at risk of dust, vapour, or gas explosions.

// Parameters

Technical data

ATEX certificate No.
OBAC 14 ATEX 0055X
Analog sensor type
PT1000-550
Bimetallic sensor type
S01.085.05.0150/0150
Channels
2 outputs: A1/A2 analog, B1/B2 bimetallic 85°C
Maximum connecting cable length
25 m
Bimetallic sensor reset hysteresis
35°C
Device category
I M1
Design type
Ex ia I Ma
Ambient temperature
0°C to 40°C
Temperature measurement range
0°C to 150°C
Air humidity
max. 95%
Enclosure protection rating
IP54
Dimensions
127 x 84 x 68 mm
Number of cable glands/connectors
2 (DP type M25x1.5)
Weight
1 kg
Mechanical impacts
high vibrations and shocks
// Classification