IPE, IPE-Dn - Intrinsically safe electromagnetic flow meter

You will measure the flow of a conductive liquid with an accuracy of 0.5% in a dewatering, firefighting, or air conditioning installation.

Iskrobezpieczny przepływomierz elektromagnetyczny IPE zamontowany w instalacji rurociągowej instalacji przemysłowej zakładu

// DESCRIPTION

What it is

The IPE intrinsically safe electromagnetic flow meter consists of a transmitter and a measuring head. The transmitter powers the head, processes its signals along with signals from external sensors, displays the measured values, and sends the result using the MODBUS RTU protocol.

You can install it in pipeline installations—in main dewatering, firefighting installations, air conditioning, and high‑pressure water emulsion chillers. Four inputs for external PT‑1000 sensors and one analog input, 0‑10V or 4‑20mA, will allow you to simultaneously measure pressure, temperature, and other parameters.

The intrinsically safe equipment enables operation in mining facilities, in rooms with degree a, b, and c methane explosion hazards and A and B coal dust explosion hazards.

// Parameters

Technical data

ATEX certificate No.
FTZÚ 09 ATEX 0236X
Power supply voltage (IPE/…/12 version)
10 ÷ 12 VDC (max. 12.8 VDC)
Power supply voltage (IPE/…/15 version)
12.5 ÷ 15 VDC (max. 15.8 VDC)
Supply current
< 300 mA
Accuracy
0.5%
Device category
I M1
Explosion protection type
Ex ia I Ma
Gas explosion group
I
Operating temperature range
0°C to 40°C
Air humidity
max. 95%
Enclosure protection rating
IP65