AT-GAS/B/HT - Temperature and Humidity Sensor

The AT‑GAS/B/HT is an intrinsically safe measuring head with a built‑in temperature and humidity transducer, designed for continuous measurement of air temperature and humidity.

ATUT Gas Detection System – AT-GAS/B/HT - Temperature and Humidity Sensor

// DESCRIPTION

What it is

Its intrinsically safe design allows operation in demanding industrial conditions, including mines with a methane explosion hazard. The terminal compartment is fitted with terminal strips and cable entries for easy connection of power and signal lines to host systems, controllers and other cooperating devices.

Its enclosure houses the electronic module with a built‑in measuring transducer, which converts the measured value into a digital signal transmitted over an RS485 interface.

The device is part of the AT‑GAS measurement and visualisation system, which consists of the AT‑GAS/A visualisation panel and the AT‑GAS/B measuring heads.

// Features

What it does

01

Measurements

  • Humidity measurement in the 0‑100% range and temperature measurement in the 0‑120 °C range
  • Measurement accuracy: 3% RH, 1°C temp.
  • Part of the AT‑GAS measurement and visualisation system (works with the AT‑GAS/A)
02

Design and Data Transmission

  • Intrinsically safe Ex ia design - Group I (M1) and Group II (2G)
  • IP65‑rated enclosure
  • Operating range: -20…+45 °C, humidity up to 95%
  • RS485 digital output - direct integration with controllers and host systems
  • Low current draw: < 25 mA at 15 V DC
  • Terminal compartment with terminals and cable entries
// Application

Where it works

01

  • Hazardous areas with explosive gas atmospheres
  • Safety and environmental monitoring systems
  • Industrial installations requiring continuous atmosphere monitoring
// Parameters

Technical data

Ex marking of the AT-GAS/B/HT measuring head
I M1 Ex ia I Ma, II 2G Ex ia IIA T3 Gb
Supply voltage
10 to 15V DC
Current draw at 15 V supply
< 25mA
Measuring range
0 - 100% RH, 0 - 120°C
Measurement accuracy
3% RH, 1°C temp.
Operating temperature
-20°C to +45 °C
Relative humidity
<95%
Mechanical hazard
low
Degree of protection
IP65
Dimensions (W × H × D)
178 x 148 x 100 mm
Weight
< 2kg