Skip to content
ATUT logoEuropean Funds
// Rozwiązanie

Gas monitoring

Continuous measurement of atmospheric parameters, gas concentrations and hazards, before they become dangerous.

1 system · solution “Gas monitoring”
  1. // Gas and atmosphere detection · /systemy/gazometriaGas monitoringMethane and other hazardous gases do not provide warnings. Mine gas monitoring does. Fast‑response sensors measure gas concentrations and air quality in designated zones non‑stop, before it gets dangerous.
14 devices · solution “Gas monitoring”
  1. /urzadzenia/at-gas-aAT-GAS/A - Visualisation PanelAT‑GAS/A is an intrinsically safe display panel that works with a sensor head (as part of a measuring and display assembly) to continuously monitor gas concentrations and selected environmental parameters.
  2. /urzadzenia/at-gas-b-airAT-GAS/B/AIR - AnemometerThe AT‑GAS/B/AIR is an intrinsically safe measuring head with a built‑in anemometer, designed for continuous measurement of air flow velocity.
  3. /urzadzenia/at-gas-b-ch4AT-GAS/B/CH4 - Methane Concentration SensorThe AT‑GAS/B/CH4 is an intrinsically safe device for continuous monitoring of methane concentration.
  4. /urzadzenia/at-gas-b-coAT-GAS/B/CO - Carbon Monoxide Concentration SensorThe AT‑GAS/B/CO is an intrinsically safe measuring head designed for continuous monitoring of carbon monoxide concentration.
  5. /urzadzenia/at-gas-b-co2AT-GAS/B/CO2 - Carbon Dioxide Concentration SensorThe AT‑GAS/B/CO2 is an intrinsically safe measuring head designed for continuous monitoring of carbon dioxide concentration.
  6. /urzadzenia/at-gas-b-h2AT-GAS/B/H2 - Hydrogen Concentration SensorThe AT‑GAS/B/H2 is an intrinsically safe measuring head designed for continuous monitoring of hydrogen concentration.
  7. /urzadzenia/at-gas-b-h2sAT-GAS/B/H2S - Hydrogen Sulphide Concentration SensorThe AT‑GAS/B/H2S is an intrinsically safe measuring head designed for continuous monitoring of hydrogen sulphide concentration.
  8. /urzadzenia/at-gas-b-o2AT-GAS/B/O2 - Oxygen Concentration SensorThe AT‑GAS/B/O2 is an intrinsically safe measuring head designed for continuous monitoring of oxygen concentration.
  9. /urzadzenia/at-gas-b-htAT-GAS/B/TH - Temperature and Humidity SensorThe AT‑GAS/B/TH is an intrinsically safe measuring head with a built‑in temperature and humidity transducer, designed for continuous measurement of air temperature and humidity.
  10. /urzadzenia/at-gas-c-airAT-GAS/C/AIR - AnemometerThe AT‑GAS/C/AIR is an airflow velocity sensor designed for hazardous areas.
  11. /urzadzenia/at-gas-c-ch4AT-GAS/C/CH4 - Methane Concentration SensorThe AT‑GAS/C/CH4 is a methane concentration sensor designed for hazardous areas.
  12. /urzadzenia/at-gas-c-coAT-GAS/C/CO - Carbon Monoxide Concentration SensorThe AT‑GAS/C/CO is a carbon monoxide concentration sensor designed for hazardous areas.
  13. /urzadzenia/at-gas-c-h2AT-GAS/C/H2 - Hydrogen Concentration SensorThe AT‑GAS/C/H2 is a hydrogen concentration sensor designed for hazardous areas.