Skip to content
ATUT logoEuropean Funds
// DEVICE

AT-GAS/C/CH4 - Methane Concentration Sensor

The AT‑GAS/C/CH4 is a methane concentration sensor designed for hazardous areas.

ATUT Gas Detection System – AT-GAS/C/CH4 - Methane Concentration Sensor

// DESCRIPTION

What it is

The sensor has two displays: one shows the communication parameters and is used during calibration, the other continuously displays the measured methane concentration. The device is equipped with four dry contacts, a 4÷20 mA current output, a 5÷15 Hz frequency output and four 4‑state inputs. The built‑in battery allows operation without external power for at least 8 hours. The sensor can be connected to a gas monitoring system PLC via RS485 (Modbus RTU) or operate as a stand‑alone device.

The measuring head provides high‑resolution measurement over the full range of 0÷100% CH4. Alarm states are signalled by a red LED and a buzzer (up to 97 dB). The sensor is additionally equipped with a temperature and humidity sensor.

// Features

What it does

01

Measurements

  • Methane concentration measurement over 0÷100% CH4 (low range 0÷5%, high range 5÷100% CH4)
  • Accuracy: ±0.2% CH4 (0÷2.5%), ±0.5% CH4 (2.5÷5%), ±5% CH4 (5÷100%)
  • Pelistor measuring head
  • 2 warning set points, adjustable within the entire range
  • Reading shown on site and in the monitoring software, delay ≤ 100 ms
02

Design and Data Transmission

  • Intrinsically safe Ex ia design - Group I (M1)
  • IP65‑rated enclosure
  • Operating range: -20 to +40 °C, humidity up to 95% (non‑condensing)
  • Outputs: 4 contacts, 4÷20 mA, 5÷15 Hz, RS485 (Modbus RTU); four 4‑state inputs
  • Built‑in battery - at least 8 h without external power
  • Alarm signalling: red LED and buzzer up to 97 dB
// Application

Where it works

01

  • Hazardous areas with explosive gas atmospheres
  • Process gas monitoring
  • Safety and environmental monitoring systems
  • Industrial installations requiring continuous atmosphere monitoring
// Parameters

Technical data

ATEX certificate number
KDB 25ATEX0028
Power supply
Intrinsically safe power supply
Supply voltage
UN = 10÷15 VDC
Current consumption
<130 mA
Built-in battery
Intrinsically safe, capacity 2200 mAh, I M1 Ex ia I Ma
Type of measuring head
Pelistor
Measurement method
Continuous
Measuring range
0÷100% CH4 (v/v); – low range: 0÷5% CH4; – high range: 5÷100% CH4
Warning threshold setting
Freely adjustable within the measuring range
Accuracy
±0.2% CH4 (range 0÷2.5% CH4); ±0.5% CH4 (range 2.5÷5% CH4); ±5% CH4 (range 5÷100% CH4)
Alarm signalling: acoustic
Buzzer, up to 97 dB
Alarm signalling: optical
Red LED
Inputs
Four 4-state inputs
Outputs
Four dry contacts; Current output 4÷20 mA; Frequency output 5÷15 Hz; RS485 (Modbus RTU)
Warning signal (to the data transmission cabinet)
Digital
Warning set points
2, adjustable within the entire measuring range
Display and transmission
Methane concentration is displayed at the measuring point and transmitted to the monitoring software; delay ≤100 ms
Explosion protection
I M1 Ex ia I Ma
Working temperature range
−20÷40 °C
Working humidity range
0÷95% RH (non-condensing)
Casing protection degree
IP65
Dimensions (W × H × D)
~322 × 220.5 × 165 mm
Cable glands / connectors
6
Weight
4 kg
// Classification
Version
  • Iskrobezpieczeństwo (Ex i)
  • ATEX
  • Ex