AT-GAS/C/AIR - Anemometer

The AT‑GAS/C/AIR is an airflow velocity sensor designed for hazardous areas.

ATUT Gas Detection System – AT-GAS/C/AIR - Anemometer

// DESCRIPTION

What it is

The sensor has two displays: one shows the communication parameters, the other continuously displays the measured airflow velocity. The device is equipped with four dry contacts, a 4÷20 mA current output, a 5÷15 Hz frequency output and four 4‑state inputs. The built‑in battery allows operation without external power for at least 8 hours. The sensor can be connected to a gas monitoring system PLC via RS485 (Modbus RTU) or operate as a stand‑alone device.

The SDP33 differential pressure measuring head provides high‑resolution airflow measurement in the range from −14 to +14 m/s. The device is factory calibrated and does not require further calibration. Alarm states are signalled by a red LED and a buzzer (up to 97 dB). The sensor is additionally equipped with a temperature and humidity sensor.

// Features

What it does

01

Measurements

  • Airflow velocity measurement from -14 to +14 m/s
  • Accuracy: ±2%
  • SDP33 differential pressure head, factory calibrated
  • 2 warning set points, adjustable within the entire range
  • Reading shown on site and in the monitoring software, delay ≤ 100 ms
02

Design and Data Transmission

  • Intrinsically safe Ex ia design - Group I (M1) and Group II (2G)
  • IP65‑rated enclosure
  • Operating range: -20 to +45 °C, humidity up to 95% (non‑condensing)
  • Outputs: 4 contacts, 4÷20 mA, 5÷15 Hz, RS485 (Modbus RTU); four 4‑state inputs
  • Built‑in battery - at least 8 h without external power
  • Alarm signalling: red LED and buzzer up to 97 dB
// Application

Where it works

01

  • Ventilation monitoring of mine workings and tunnels - both during tunnelling and throughout tunnel operation and maintenance
  • Monitoring of air velocity and flow direction in shafts, roadways and ventilation ducts
  • Safety and environmental monitoring systems
  • Hazardous areas with explosive gas atmospheres
// Parameters

Technical data

ATEX certificate number
KDB 25ATEX0028
Power supply
Intrinsically safe power supply
Supply voltage
UN = 10÷15 VDC
Current consumption
<130 mA
Built-in battery
Intrinsically safe, capacity 2200 mAh, I M1 Ex ia I Ma
Type of measuring head
Differential pressure (SDP33)
Measurement method
Continuous
Measuring range
−14÷+14 m/s
Accuracy
±2%
Alarm signalling: acoustic
Buzzer, up to 97 dB
Alarm signalling: optical
Red LED
Inputs
Four 4-state inputs
Outputs
Four programmable NO relay contacts (triggered at a set value); Current output 4÷20 mA; Frequency output 5÷15 Hz; RS485 (Modbus RTU)
Warning signal (to the data transmission cabinet)
Digital
Warning set points
2, adjustable within the entire measuring range
Display and transmission
Airflow velocity is displayed at the measuring point and transmitted to the monitoring software; delay ≤100 ms
Explosion protection
I M1 Ex ia I Ma; II 2G Ex ia IIA T3 Gb
Working temperature range
−20÷45 °C
Working humidity range
0÷95% RH (non-condensing)
Casing protection degree
IP65
Dimensions (W × H × D)
~322 × 220.5 × 165 mm
Cable glands / connectors
6
Weight
4 kg
// Classification
Version
  • Iskrobezpieczeństwo (Ex i)
  • ATEX
  • Ex