- ATEX certificate number
- KDB 25ATEX0028
- Power supply
- Intrinsically safe power supply
- Supply voltage
- UN = 10÷15 VDC
- Current consumption
- <130 mA
- Built-in battery
- Intrinsically safe, capacity 2200 mAh, I M1 Ex ia I Ma
- Type of measuring head
- Differential pressure (SDP33)
- Measurement method
- Continuous
- Measuring range
- −14÷+14 m/s
- Accuracy
- ±2%
- Alarm signalling: acoustic
- Buzzer, up to 97 dB
- Alarm signalling: optical
- Red LED
- Inputs
- Four 4-state inputs
- Outputs
- Four programmable NO relay contacts (triggered at a set value); Current output 4÷20 mA; Frequency output 5÷15 Hz; RS485 (Modbus RTU)
- Warning signal (to the data transmission cabinet)
- Digital
- Warning set points
- 2, adjustable within the entire measuring range
- Display and transmission
- Airflow velocity is displayed at the measuring point and transmitted to the monitoring software; delay ≤100 ms
- Explosion protection
- I M1 Ex ia I Ma; II 2G Ex ia IIA T3 Gb
- Working temperature range
- −20÷45 °C
- Working humidity range
- 0÷95% RH (non-condensing)
- Casing protection degree
- IP65
- Dimensions (W × H × D)
- ~322 × 220.5 × 165 mm
- Cable glands / connectors
- 6
- Weight
- 4 kg