Skip to content
ATUT logo
// DEVICE

OP-1 - Flameproof (Ex d) fibre-optic gland

A flameproof (Ex d) gland for optical and electrical connections between explosion‑protected enclosures. It connects one flameproof (Ex d) enclosure with another, in accordance with the PN‑EN 60079‑0 standard.

Ognioszczelny przepust światłowodowy OP-1, widok złącza

// DESCRIPTION

What it is

OP‑1 makes optical and electrical connections in explosion‑protected enclosures, between one flameproof (Ex d) enclosure and another in an explosion‑protected design complying with the PN‑EN 60079‑0 standard, or between different flameproof (Ex d) enclosures.

The OP‑1/S/* version guides a single‑mode 9/125 μm fibre‑optic patchcord; the OP‑1/P/* version guides a 0.5 mm² electrical wire for 5 A. The gland accommodates up to 10 wires, within an M36 x 1.5 thread, and operates in any position.

Device category I M2, explosion‑protected Ex d I Mb design, ATEX certificate KDB 11 ATEX 146U.

// Parameters

Technical data

ATEX certificate No.
KDB 11 ATEX 146U
Gland dimension
M36 x 1.5 g6
Number of wires
10
Device category
I M2
Explosion protection type
Ex d I Mb